Zhou Wanging, Li Xianwu. Axial Load Testing of Super Length PHC Pipe Piles[J]. GEOTECHNICAL ENGINEERING TECHNIQUE, 2010, 24(4): 207-210. doi: 10.3969/j.issn.1007-2993.2010.04.011
Citation: Zhou Wanging, Li Xianwu. Axial Load Testing of Super Length PHC Pipe Piles[J]. GEOTECHNICAL ENGINEERING TECHNIQUE, 2010, 24(4): 207-210. doi: 10.3969/j.issn.1007-2993.2010.04.011

Axial Load Testing of Super Length PHC Pipe Piles

doi: 10.3969/j.issn.1007-2993.2010.04.011
  • Received Date: 2010-03-16
    Available Online: 2021-07-06
  • The bearing capacity behavior and load transfer mechanism are discussed through static and high strain dynamic pile load testing. Results show that the total bearing capacity of test piles by high strain dynamic testing is approximately equal to that by static testing. The lateral friction resistance by dynamic testing is consistent with that by static testing at the depth of 0-30m,but is much larger than that by static testing when the length of the pile exceeds 30 m.

     