The bending moment and shearing stress induced by water-soil pressure are converted into the normal stress by the cement-soil retaining structure with the continuous arches,and these better the stress condition greatly. According to the stress characteristics of the combined arches,the interior force is analysed and calculated. The design method of protecting structure with the continuous arches is put forward,and the calculation of a project example is given.