It is necessary to consider the influence of shrinking and temperature stresses when using reinforced stress to measure reinforced concrete strut axial forces. According to an engineering practice in Pudong, Shanghai, both the theoretical analysis and in-situ test are studied. The results show that the shrinking and maximum temperature stresses correspond to 1/3 and 1/5 of the total strut axial forces respectively.